Safety First!

 

 



 


Air Emissions Testing Q&E

Client: DÜRR Environmental, Inc.
Project: Air Emissions Testing, General Motors Corporation
Location
: Defiance, Ohio


Copyright AST Environmental  

Description: A.S.T. performed air emissions testing on a regenerative catalytic oxidizer that is part of an aluminum casting line. The testing was conducted on the inlet and outlet simultaneously using Method 7E for the determination of NOx and Method 25A for the determination of Volatile Organic Compound (VOC) concentrations. We utilized a dual analyzer process during the test runs to obtain methane and total gaseous non-methane organic concentrations.

Client: AK Steel Company
Project: Air Emissions Testing
Location
: Middletown, Ohio and Rockport, Indiana

Description: A.S.T. has conducted air emissions sampling at two AK Steel facilities. All testing was coordinated with the state regulatory agencies. The testing was conducted using the following methods: 40 CFR, Part 60, Performance Specifications 2 and 3, for determination of NOx concentrations and Relative Accuracy Testing Audit of the NOx analyzer, EPA Reference Methods 1-4 and 7E for the determination of NOx concentrations and EPA Reference Methods 1-5 and 202 for the determination of total filterable and condensable particulate emissions.

For more information about our projects, please Contact A.S.T. or see the Air Emissions Testing on-line PowerPoint® slide show that is available on our Downloads and Additional Information page.